100A 8 Spaces/15 Circuit QO Sub Panel

Article#02655003 Model#QO8L100S Format100Ax3Wx120/240V
100A 8 Spaces/15 Circuit QO Sub Panel
 

Description

Main lugs loadcentres typically are used as an add-on load center and is connected to the service entrance loadcentre when spaces for more circuits are needed or when a main disconnect is located elsewhere. It does not contain a main breaker. 8 Spaces, expandable to 15 circuits maximum with the use of QO Tandem breakers. Type 1 Indoor Enclosure with surface mounted trim. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Main Wire Size - AWG/kcmil Al/Cu: #8-1.

Technical specifications

You may also like

SIEMENS
Panel - 100 A - 8/16 Circuit "Siemens" Electric Panel
Format 100AM
Article #2263012
Model #EQL8100D
★★★★★ ★★★★★
0
(0)
SIEMENS
240 VAC 100 A EQL Load Center Single Phase and 3 Wires
Format 100AM
Article #2263011
Model #EQL4100
★★★★★ ★★★★★
0
(0)
SIEMENS
240 VAC 60 A EQL Load Center Single Phase and 3 Wires
Format 60AM
Article #2263010
Model #EQL260S
★★★★★ ★★★★★
0
(0)
SIEMENS
Main Panel + Breaker X-Press Pack - 24/48 Circuits - 100 A
Format 100-24/48
Article #22635045
Model #XP24100Q
★★★★★ ★★★★★
0
(0)
SIEMENS
Load Centre Main Lugs - 12 to 24 Circuits - 125A/240V - Grey
Format 125AM-12/24
Article #22635052
Model #EQL12125D
★★★★★ ★★★★★
0
(0)
SQUARE D
6-Circuits Breaker Box
Format 100AX120/240V
Article #0265036
Model #QO6L100S
★★★★★ ★★★★★
5
(2)
SIEMENS
Outdoor Circuit Panel - 4/8 - 125V 120/240 V
Format 125AM 4/8
Article #88665019
Model #W0408ML1125-GRD
★★★★★ ★★★★★
0
(0)
SIEMENS
240 VAC 60A Service Entrance Load Center Single Phase/3-Wire
Format 60A 120/240V
Article #88665001
Model #SEQ12060SM
★★★★★ ★★★★★
0
(0)
SQUARE D
100-A 32 Spaces QO Panel Package
Format 100Ax32CIRC.
Article #0265059
Model #QP32100
★★★★★ ★★★★★
5
(1)
SQUARE D
Electrical Panel QO - 125 A - 24/48
Format 125AM 24/48
Article #02655139
Model #CQO124L125PGC
★★★★★ ★★★★★
5
(1)
SQUARE D
60A Air Conditioner Disconnect
Format 60A
Article #02655079
Model #CQO200TR
★★★★★ ★★★★★
0
(0)
SQUARE D
100A 4 Spaces/8 Circuit QO Sub Panel
Format 100AX120/240V
Article #0265035
Model #QO4L100S
★★★★★ ★★★★★
0
(0)
SIEMENS
Electric Panel for Spa
Format 125A-120/240V
Article #88665004
Model #W0408ML1125-60
★★★★★ ★★★★★
0
(0)
SQUARE D
Electrical Panel with Main Breaker - 100A/24 - 240 V
Format 100AM
Article #02655137
Model #CQO124M100PC
★★★★★ ★★★★★
0
(0)
CUTLER-HAMMER
8/16 Main Circuit Breaker
Format 100Ax8/16CIRC
Article #1334032
Model #CCPL108
★★★★★ ★★★★★
0
(0)
SQUARE D
Square D(TM) Circuit Breaker Box - 12 Spaces/24 Circuits
Article #02655138
Model #CQO112L100PGC
★★★★★ ★★★★★
0
(0)
SIEMENS
Electrical panel
Format 200Ax40/80
Article #22635046
Model #XP40200Q
★★★★★ ★★★★★
0
(0)
SQUARE D
70-A 2 circuits QO Sub Panel
Format 70A
Article #0265037
Model #QO2L70S
★★★★★ ★★★★★
0
(0)
SQUARE D
100A 24 Spaces/48 Circuit QO Panel Package
Format 100A
Article #0265060
Model #QP24100
★★★★★ ★★★★★
4.5
(2)
SIEMENS
100A Electrical Panel with 24 Circuits Expandable to 48
Format 100A-24/48
Article #88665005
Model #XP24100AF
★★★★★ ★★★★★
0
(0)
SQUARE D
30A Square D Generator Panel with 18 Spaces/36 Circuits
Format 30A-36CC-120/240V
Article #02655108
Model #QOGP3P3036P
★★★★★ ★★★★★
5
(1)
SQUARE D
200A 40 Spaces/80 Circuit QO Panel Package with Breakers
Format 200Ax40CIRC
Article #0265061
Model #QP40200
★★★★★ ★★★★★
0
(0)
SQUARE D
60A Square D Generator Panel with 18 Spaces/36 Circuits
Format 60A-36CC-120/240V
Article #02655109
Model #QOGP3P6036
★★★★★ ★★★★★
5
(2)
SIEMENS
32/64 Circuit Panel with Breaker
Format 100AM 32/64
Article #22635044
Model #XP32100AF
★★★★★ ★★★★★
0
(0)
HOMELINE
15/15A/1P - 20A/2P CHOM QUAD Circuit Breaker
Format 15-20Ax120/250Vx2P
Article #02655104
Model #CHOMT1515220CP
★★★★★ ★★★★★
0
(0)

I'm a little confused: This is a 100 amp panel, but the description says that the "main wire size" is #8 ... As I understand it, #8 wire is only rated for 50 amps, so how am I supposed to feed 60 (or more) amps to this thing if I can only #8 feeder cable?

Asked by: Confusion
It's not well explained at a DIY'er level in the description above, but the wire size mentioned is a range that the panel (and lugs) can handle - in this case from a minimum of #8 to a maximum of #1.
Answered by: Sparker
Date published: 2018-11-21
  • y_2020, m_9, d_28, h_15CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.12
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_02655003, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_renodepot
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Changing store

You are about to change your selected store.

Please note that if you change stores, prices and availability shown on the website may vary and your shopping cart will empty.

Keep my store Change store